Contact

ŁIPMO

CONNECTOR FOR INSULATION WITH POLYAMIDE STUD
WITH EXTENDED EXPANSION ZONE

INDEXCONNECTOR LENGTH L [mm]INSULATION MATERIAL
THICKNESS [mm]
QUANTITY [pcs]
ŁIPMO-14014050-60200
ŁIPMO-16016070-80200
ŁIPMO-18018090-100200
ŁIPMO-200200110-120200
ŁIPMO-220220130-140200
ŁIPMO-260260170-180100
ŁIPMO-300*300210-220100
ŁIPMO-350*350260-270100
ŁIPMO-400*400310-320100

*Available from 2023

EXTENDED EXPANSION ZONE

TECHNICAL SPECIFICATION:

1) Drill a hole in the wall using a rotary drill
2) Place the connector in the hole
3) Anchor the connector by hammering the stud
4) Correctly installed insulation connector
CHARACTERISTIC RESISTANCE TO TENSION LOADS NRk IN CONCRETE AND IN MANSORY FOR SINGLE ŁIPMO ANCHOR
BASEVOLUME DENSITY [ kg / dm³ ]MINIMUM RESISTANCE
TO COMPRESSION
[ N / mm² ]
ACCORDING TO
APPLICABLE
STANDARD
NRk [ kN ]
Concrete C12/15 (use category A)EN 2060,55
Concrete C16/20 to C50/60 (use category A)EN 2060,80
Clay bricks MZ (use category B)≥2,0≥20,0EN 771-10,60
Calcium silicate bricks KS (use category B)≥2,0≥20,0EN 771-20,65
Vertically perforated clay bricks Porotherm 25 P+D (use category C)≥0,8≥15,0EN 771-10,25
Calcium silicate hollow blocks KSL (use category C)≥1,6≥15,0EN 771-20,25
Lightweight concrete blocks LAC (use category D)≥0,88≥5,0EN 771-30,30
Autoclaved concrete blocks LAC (use category E)≥ 0,35≥2,0EN771-40,10
Partial safety factor for anchor resistance, ɣM (1)2,0

1) Applicable if no domestic regulations

CORRECT LAYOUT OF CONNECTORS
IN FAÇADE INSULATION

Minimum base thickness - h [mm]100
Minimum connector spacing - smin [mm]100
Minimum distance between the connector and the base - cmin [mm]100