ŁIMO

CONNECTOR FOR INSULATION WITH METAL STUD
AND POLYAMIDE HEAD SHORT EXPANSION ZONE

INDEXCONNECTOR LENGTH L [mm]INSULATION MATERIAL
THICKNESS [mm]
QUANTITY [pcs]
ŁIMO-12012060-70200
ŁIMO-14014080-90200
ŁIMO-160160100-110200
ŁIMO-180180120-130200
ŁIMO-200200150-170200
ŁIMO-220220150-170200
ŁIMO-260260200-210100
ŁIMO-300*300240-250100
ŁIMO-350*350290-300100
ŁIMO-400*400340-350100

*Available from 2023

SHORT EXPANSION ZONE

TECHNICAL SPECIFICATION:

1) Drill a hole in the wall using a hammer drill and thoroughly remove chips
2) Place the connector in the hole
3) Anchor the connector by hammering the stud
4) Correctly installed insulation connector

CHARACTERISTIC RESISTANCE TO TENSION LOADS NRk IN CONCRETE AND IN MANSORY FOR SINGLE ŁIMO ANCHOR

BASEVOLUME DENSITY [ kg / dm³ ]MINIMUM RESISTANCE
TO COMPRESSION
[ N / mm² ]
ACCORDING TO
APPLICABLE
STANDARD
NRk [ kN ]
Concrete C12/15 (use category A)EN 2060,40
Concrete C16/20 to C50/60 (use category A)EN 2060,55
Clay bricks MZ (use category B)≥2,0≥20,0EN 771-10,65
Calcium silicate bricks KS (use category B)≥2,0≥20,0EN 771-20,35
Vertically perforated clay bricks Porotherm 25 P+D (use category C)≥0,8≥15,0EN 771-10,10
Calcium silicate hollow blocks KSL (use category C)≥1,6≥15,0EN 771-20,40
Lightweight concrete blocks LAC (use category D)≥0,88≥5,0EN 771-30,30
Autoclaved concrete blocks LAC (use category E)≥ 0,35≥2,0EN771-40,10
Partial safety factor for anchor resistance, ɣM (1)2,0

1) Applicable if no domestic regulations

CORRECT LAYOUT OF CONNECTORS
IN FAÇADE INSULATION

Minimum base thickness - h [mm]100
Minimum connector spacing - smin [mm]100
Minimum distance between the connector and the base - cmin [mm]100

APPROVALS TO DOWNLOAD:

OTHER PRODUCTS: